Abstract
The voltage resonant inverter with parallel connection of arbitrary numbers of half bridge sections as electronic ballast output stage for high pressure sodium lamps is analyzed. The analytical expressions for n-sections inverter currents and powers are obtained, the features of its power phase control are considered. References 7, figures 5.
References
Evstifeev A. The features of construction of ballasts for high pressure lamps (HID lamp ballasts) // Silovaia elektronika. – 2008. – No 3. – Pp. 132–136. (Rus)
Meleshin V. Transistor conversion technology. – Moskva: Tekhnosfera, 2005. – 632 p. (Rus)
Yurchenko O.M., Gutsaliuk V.Ya., Gerasymenko P.Yu., Slesarevskyi I.O. Mathematical model of resonance transistor voltage inverter with low frequency pulse modulation // Tekhnichna elektrodynamika. – 2011. – No 1. – Pp. 24–30. (Ukr)
High pressure sodium lamps. Operating standard. ГОСТ Р 53073-2008 (IEC 60662:2002) // Moskva: Standartinform, 2009. – 53 p. (Rus)
Branas C., Azcondo F.J., Casanueva R., Bracho S. Phase-controlled Quadruple LCp Resonant Inverter to drive 600W HPS Lamps // IEEE Transactions on Power Electronics. – 2007. – Vol. 22. – No 3. – Pp. 831–838.
Czarkowski D., Kazimierczuk M.K. Phase-controlled series-parallel resonant converter // IEEE Transactions on Power Electronics. – 1993. – Vol. 8. – No 3. – Pp. 309–319.
Epron S., Aubes M., Damelincourt J.J., Cojocaru A.P. Acoustic resonance phenomena in high pressure discharge lamps // High Temperature Material Processes. – 1999. – Vol. 3. – Pp. 141–155.