Abstract
The principle of operation of the parallel type active power line conditioner with self-discharge current of the battery compensation is proposed. A simplified diagram of the device with the description of the main elements and blocks presented. Equivalent circuits of active power line conditioner with charger at work intervals are shown. Expressions of compensator currents at appropriate intervals of work are obtained. References 3, table 1, figure 1.
References
Zhuikov V.Ya., Nguyen Lyhai Tung. Condition of reactive power compensation by parallel type high frequency converter // Elektronika i sviaz. – 1998. – №5. – Pp. 82–85. (Rus)
Volkivskii V.B., Kamaev V.S., Kolodiazhnyi A.V. Methods of charging nickel-cadmium batteries // Elektronika i sviaz. – 2005. – № 27. – Pp. 18–25. (Rus)
Mikolaets D.A. The balance of power in the parallel compensator with a narrow loading current // Energosberezhenie, energetika, energoaudit. Spetsialnyi vypusk. Part 2. – 2013. – Vol. 8(114). – Pp. 96–98. (Ukr)

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
Copyright (c) 2023 Array