Abstract
The physical processes in the damping system of the salient-pole synchronous machine rotor, which cause the gradual destruction of its structure, have been studied. In particular, the distributions of currents, temperatures and thermomechanical stresses in the damping system rods during its operation in asynchronous and asymmetric modes of operation, as well as in case of rotor eccentricity. A field mathematical model has been developed that takes into account the combined action of three physical fields of different nature: electromagnetic, temperaturic, and thermomechanical stress fields, and allows estimating heating and thermomechanical loads in the damping system of the rotor of the salient-pole synchronous machine. According to the results of the analysis, the heating and thermomechanical loads of the structural elements were determined and recommendations for its structural improvement were given. References 9, figures 9, tables 1.
References
Artyukh S.F., Urmanov O.B. Statistical analysis of electrical equipment failures at hydroelectric power stations of the Kiev hydroelectric station cascade of the HPP-PSP. Visnyk Natsionalnoho Tekhnichnoho Universytetu Kharkivskii Politekhnichni Iinstytut. 2011. No 41. Pp. 3-7. (Rus)
Vaskovsky Yu.M., Civinskyi S.S., Titko O.I. Electromagnetic processes in the rotor damping system of a hydro-generator with unevenness of the air gap. Tekhnichna Elektrodynamika. 2015. No 1. Pp. 65-71. (Ukr)
Vaskovsky Yu.M., Potashnik S.I., Fedorenko G.M. Improving the reliability, level of safety and efficiency of the of damping systems functioning of powerful hydrogenerators. Hidroenergetika Ukrayini. 2009. No 4. Pp. 28-34. (Ukr)
Vaskovsky Yu.N., Geraskin A.A. Vibroperturbing electromagnetic forces in squirrel-cage induction motors in the presence of damage in their construction. Tekhnichna Elektrodynamika. 2010. No 5. Pp. 31-38. (Rus)
GOST 5616-89: Hydro-turbine electric generators and generators-motors. General technical conditions. Moskva, IPK, Szdatelstvo standartovo, 2003, 18 p. (Rus)
Mesnyankin S.Yu., Dikov A.V. Calculation of power plants elements contact thermal resistance with wavy sur-faces Trudy MAI. 2014. No 8. Pp. 46-51. (Rus)
Shlykov A.P., Ganin E.A. Thermal contact resistance. Atomnaya energiya.1960. No 9. Pp.35-34. (Rus)
Yong Liao, Zhen Nan Fan, Li Han, Li Dan Xie. Analysis of the Loss and Heat on Damper Bars in Large Tubular Hydro-Generator base on the 3D Electromagnetic-Temperature field Calculation. Przegląd Elektrotechniczny (Electri-cal Review). 2012. R. 88 NR 5b. Pp. 97-100.
Karmaker H.C. Broken Damper Bar Detection Studies Using Flux Probe Measurements and Time-Stepping Finite Element Analysis for Salient-Pole Synchronous Machines. 4th IEEE International Symposium on Diagnostics for Elec-tric Machines, Power Electronics and Drives (SDEMPED 2003). Atlanta, GA, USA, August 24-26, 2003. Pp.193-197.

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
Copyright (c) 2021 Array