INVESTIGATION OF THE INPUT CURRENT SPECTRUM OF HIGH-FREQUENCY POWER FACTOR CORRECTORS
ARTICLE_26_PDF (Українська)

Keywords

power factor corrector
spectrum
current
control method коректор коефіцієнта потужності
спектр
струм
метод керування

How to Cite

[1]
Rohal, V. and Demchenko, Y. 2014. INVESTIGATION OF THE INPUT CURRENT SPECTRUM OF HIGH-FREQUENCY POWER FACTOR CORRECTORS. Tekhnichna Elektrodynamika. 5 (Aug. 2014), 080.

Abstract

The investigation of the input current spectrum of the active high-frequency power factor correctors based on a boost converter is conducted. In the MATLAB/Simulink environment the models of correctors, whose control system implements the borderline control method, peak and average current control methods, are built. The corrector, which generates the least electromagnetic interference in the mains supply, was determined. The input current spectrum dependence on the load of the correctors was investigated. The modificated method of corrector control with the suppression of the third harmonic of the input current was offered. References 3, figures 4.

ARTICLE_26_PDF (Українська)

References

Buso S., Mattavelli P., Rossetto L., Spiazzi G. Simple Digital Control Improving Dynamic Performance of Power Factor Preregulators // IEEE Transactions on Power Electronics. – 1998. – № 5. – Pp. 814–823.

Fairchild Semiconductor Corporation. Power Factor Correction (PFC) Basics. – Application Note 42047, 2004. – 11 p.

Klimov V.P., Fedoseev V.I. Circuitry of single-phase power factor correctors // Prakticheskaia silovaia elektronika. – 2002. – №8. – Pp. 23–28. (Rus)

Creative Commons License

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.

Copyright (c) 2023 Tekhnichna Elektrodynamika

Abstract views: 134 | PDF Downloads: 18

Downloads

Download data is not yet available.