Abstract
Dependences of constants of integration on a parity between the periods of supply voltage of an operating signal and the period of own fluctuations of system are investigated at symmetric control of capacity switchings in a series RLC-circuit of sinusoidal voltage. Cases when the period of an operating signal twice more, is equal and twice less period of input voltage are considered. The analysis used methods of the theory of the differential equations with pulse action. Parities for the integration constants, the including factors depending on parameters of a circuit are received, changing which is possible in certain borders to choose quantity of the switchings necessary for achievement of the steady-state mode. References 3.
References
Samoilenko A.M., Krivosheia S.A., Perestiuk N.A. Differential equations: examples and tasks. – Moskva: Vysshaia shkola, 1989. – 383 p. (Rus)
Shidlovskaia N.A. The processes in sin voltage RLC-circuit with controlled reversing of capacity // Tekhnichna elektrodynamika. – 2011. – No 1. – Pp. 3–11. (Rus)
Shidlovskii A.K., Fedii V.S. Frequency requlating reactive power sources. – Kyiv: Naukova dumka, 1980. – 304 p. (Rus)