STUDY OF STARTING REGIMES OF INDUCTION MOTORS USING EQUIVALENT PARAMETERS OF QUASI-3D FIELD MODEL
ARTICLE_7_PDF

Keywords

induction motors
parameters of equivalent circuit
main flux reactance
field model
start асинхронний двигун
параметри заступної схеми
польова модель
пуск

How to Cite

[1]
Popovych, O. and Golovan, I. 2019. STUDY OF STARTING REGIMES OF INDUCTION MOTORS USING EQUIVALENT PARAMETERS OF QUASI-3D FIELD MODEL. Tekhnichna Elektrodynamika. 1 (Jan. 2019), 034. DOI:https://doi.org/10.15407/techned2019.01.034.

Abstract

The efficiency and adequacy of mathematical models of induction motors for dynamic operating conditions are improved due to used dependences for varied electromagnetic parameters. The dependences are based on the results of field analysis. The mathematical models with single-dimensional approximation of parameters are developed. This
simplifies the field analysis and formation of approximating dependences with continuous derivatives. The relationship between given functional dependences of electromagnetic parameters and the adequacy of mathematical models for static and dynamic conditions is studied. The expressions and method are proposed to determine the correction coefficients that improve the adequacy of the mathematical models for dynamic conditions with single-dimensional approximation of parameters. References 8, figures 3.

https://doi.org/10.15407/techned2019.01.034
ARTICLE_7_PDF

References

Lesnik V.A., Shurub Yu.V. Account of differential parameters at mathematical simulation of asymmetrical operational modes of asynchronous generators. Tekhnichna Elektrodynamika. 2003. No 1. Pp. 45-48. (Rus)

Shurub Yu.V. Statistical optimization of voltage regulated induction electric drives. Tekhnichna Elektrodynamika. 2014. No 5. Pp. 116-118. (Ukr)

Mazurenko L.I., Dzhura O.V., Shevchuk S.P. Transients in a Transistor-Switched Capacitor Regulator of a Stand-Alone Induction Generator Supplying a Single-Phase Load. International Conference on modern electrical and energy systems (MEES). Kremenchuk, Ukraine, November 15-17, 2017. Рp. 244-247. DOI: http://dx.doi.org/10.1109/MEES.2017.8248901

Vaskovskyi Yu.M., Tytko O.I., Makeykin I.S., Kravchuk V.A. Diagnosis of induction motors based on analysis of starting. Tekhnichna Elektrodynamika. 2017. No 3. Pp. 58-64. (Ukr) DOI: https://doi.org/10.15407/techned2017.03.058

Popovych O.M., Golovan І.V. Refinement of analysis operation of induction motors as part electromechanical systems using equivalenting field models using electrical circuits. Tekhnichna Elektrodynamika. 2014. No 5. Pp. 113-115. (Ukr)

Popovych O.M., Golovan І.V. Study of changed main flux reactance of squirrel-cage induction motors using field analysis of their starting characteristics. Tekhnichna Elektrodynamika. 2018. No 5. Pp. 69-72. (Ukr) DOI: https://doi.org/10.15407/techned2018.05.069

Bibik O.V., Popovych O.M., Shevchuk S.P. Effective modes of electromechanical system of pump installation of a multi-storey building. Tekhnichna Elektrodynamika. 2016. No 5. Pp. 38-45. (Ukr) DOI: https://doi.org/10.15407/techned2016.05.038

Radin V.I., Londin Y., Rozenknop V.D. The unified series of asynchronous motors Interelektro. Moskva: Energoatomizdat, 1990. 416 p.(Rus)

Creative Commons License

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.