THE UNBALANCE POWER IDENTIFICATION IN THE THREE-PHASE FOUR-WIRE POWER SUPPLY SYSTEM FOR THE NEEDS OF ITS DISTRIBUTED COMPENSATION
ARTICLE_2_PDF

Keywords

imbalance power
microgrid
shunt active filter control strategy
distributed filtering потужність небалансу
мікромережа
стратегія керування паралельним активним фільтром
розподілена фільтрація

How to Cite

[1]
Artemenko, M. et al. 2022. THE UNBALANCE POWER IDENTIFICATION IN THE THREE-PHASE FOUR-WIRE POWER SUPPLY SYSTEM FOR THE NEEDS OF ITS DISTRIBUTED COMPENSATION. Tekhnichna Elektrodynamika. 2022, 2 (Mar. 2022), 012. DOI:https://doi.org/10.15407/techned2022.02.012.

Abstract

The idea of distributed active filtration is to compensate for the currents of higher harmonics and undesirable components of the power of the main network with inverters of renewable energy converters of the connected microgrid, which have reserves of apparent power. For the convenience of distributed compensation, it is proposed to identify the sinusoidal mode of the three-phase four-wire power system, provided that the symmetric source is six mutually orthogonal components of the three-coordinate vector of line currents. The power of imbalance is shown to be due to four mutually orthogonal components of the three-coordinate vector of line currents with defined reference voltage vectors, each of which is proportional to a separate orthogonal component of the power of imbalance. Integral formulas for determining the scalar values of the four specified orthogonal components of imbalance powers have been obtained, which open the possibility of accounting for their contribution to the deterioration of the quality of electrical energy and the synthesis of control signals for active distributed filtration. The connection between the four specified orthogonal components of the power of imbalance and the parameters of the linear unbalanced load was established, which made it possible to verify these integral formulas using a computer experiment. It is analytically established and experimentally confirmed that the squares of the two orthogonal components of the imbalance powers associated with the current of the neutral wire are included in the decomposition of the square of apparent power and power losses with the multiplier, depending on the ratio of the resistances of the transmission line of the three-phase four-wire power system. References 17, figures 3.

https://doi.org/10.15407/techned2022.02.012
ARTICLE_2_PDF

References

Hryb O.H., Sokol E.I., Zharkin A.F., Vasylchenko V.I., Tesik Yu.F. Quality of electrical energy. Volume 3. Methods and means of improving the quality of electrical power. Kharkiv: Hraf-X, 2014. 292 p. (Ukr)

Definitions for the measurement of electric power quantities under sinusoidal non-sinusoidal, balanced or unbalanced conditions. IEEE Std. 1459-2010, 2010. DOI: https://doi.org/10.1109/IEEESTD.2010.5439063

Syrotyn Yu.A., Hryb O.H., Hapon D.A., Ierusalymova T.S., Shvets S.V. Accounting for inactive components of apparent power. Bulletin of NTU KhPI, Hydraulic machines and hydrounits. 2017. No 22 (1244). Pp. 71–76. (Rus)

Fortescue, C.L. Method of symmetrical coordinates applied to the solution of polyphase networks. Proc. 34th Annual Convention of the AIEE, Atlantic City, NJ, USA, 1918. Vol. 37. No 3. Pp. 1027–1140. DOI: https://doi.org/10.1109/T-AIEE.1918.4765570

Vo T., Ravishankar J., Nurdin H.I., Fletcher J. A novel controller for harmonics reduction of grid-tied converters in unbalanced networks. Electr. Power Syst. Res. 2018. Vol. 155. Pp. 296–306. DOI: https://doi.org/10.1016/j.epsr.2017.10.019

Salmerón P., Vázquez J.R., Herrera R.S., Litrán S.P. Apparent power and power factor in unbalanced and distorted systems. Applications in three phase load compensations. RE&PQJ, Vol. 1. No 5. 2007. DOI: https://doi.org/10.24084/repqj05.312

Pedro A. Blasco, Rafael Montoya-Mira, José M. Diez, Rafael Montoya. An Alternate Representation of the Vector of Apparent Power and Unbalanced Power in Three-Phase Electrical Systems. Appl. Sci. 2020. No 10. 3756. DOI: https://doi:10.3390/app10113756

Vijay A.S., Doolla Suryanarayana, Chandorkar Mukul C. Unbalance mitigation strategies in microgrids. IET Power Electron. 2020. Vol. 13. Iss. 9. Pp. 1687-1710. DOI: https://doi.org/10.1049/iet-pel.2019.1080

Artemenko M.Y., Batrak L.M., Mykhalskyi V.M., Polishchuk S.Y. Energy performance optimization of the three phase four wire power supply system with a shuntactive filter in the unbalanced sinusoidal mode. Tekhnichna elektrodynamika. 2015. No 2. Pp. 30-37. (Ukr)

Mykhalskyi V.M., Sobolev V.M., Chopyk V.V., Shapoval I.A. The minimization strategy of undesirable instantaneous power components with different topologies of shunt active filter. Tekhnichna elektrodynamika. 2014. No 1. Pp. 41-50. (Ukr)

Czarnecki L.S., Haley P.M. Unbalanced Power in Four-Wire Systems and its Reactive Compensation. IEEE Transactions on Power Delivery. IEEE Transactions on Power Delivery. 2015. Vol. 30. No 1. Pp. 53-63. DOI: https://doi.org/10.1109/TPWRD.2014.2314599

Augusto Matheus dos Santos Alonso, Danilo Iglesias Brandao, Elisabetta Tedeschi, Fernando Pinhabel Marafão. Distributed selective harmonic mitigation and decoupled unbalance compensation by coordinated inverters in three-phase four-wire low-voltage networks. Electric Power Systems Research. Sept. 2020. Vol. 186. Pp. 1–14. DOI: https://doi.org/10.1016/j.epsr.2020.106407

Guodong Liu, Thomas B. Ollis, Bailu Xiao, Xiaohu Zhang, Kevin Tomsovic. Distributed energy management for community microgrids considering phase balancing and peak shaving. IET Gener. Transm. Distrib. 2019. Vol. 13. Iss. 9. Pp. 1612-1620. DOI: https://doi.org/10.1049/iet-gtd.2018.5881

Boiko V.S., Boiko V.V., Vydolob Yu.F. Theoretical Fundamentals of Electrical Engineering: Tutorial. Steady-state modes of linear electric circles with lumped parameters. Vol. 1. Kyiv: Polytechnic Publishing House. 2004. 272 p. (Rus)

Artemenko M.Yu., Mykhalskyi V.M., Polishchuk S.Y. Definition of apparent power of three-phase power supply systems as a theoretical basis for development of energy-efficient shunt active filters. Tekhnichna elektrodynamika. 2017. No 2. Pp. 25-34. (Ukr) DOI: https://doi/org/10.15407/techned2017.02.025

Artemenko M., Batrak L., Polishchuk S. New definition formulas for apparent power and active current of three-phase power system. Przeglad Elektrotechniczny. 2019. No 95(8). Pp. 81–85. DOI: https://doi.org/10.15199/48.2019.08.20

Polishchuk S.Y., Artemenko M.Yu., Mykhalskyi V.M., Batrak L.M., Shapoval I.A. Shunt active filter control strategy with partial decrease of zero-sequence voltage in three-phase four-wire system. Tekhnichna elektrodynamika. 2013. No 3. Pp. 12-19. (Ukr)

Creative Commons License

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.

Copyright (c) 2022 Tekhnichna Elektrodynamika

Abstract views: 498 | PDF Downloads: 144

Downloads

Download data is not yet available.