Abstract
The laws of the course of the electromagnetic processes occurring in the contactless excitation system of the asynchronous generator on the basis of a cascade three-phase, three-phase voltage modulator on the possibility of expansion of the biphonal slip range of the generator are established. The method of correction of parameters of the rotors of the machines of the modulator and generator is offered, which allows to stabilize operation of the switch in the range of slip S = -1 ÷ +0,4. References 4, figures 5.
References
Yanmei Yao, Study of Induction Machines with Rotating Power Electronic Converter. Doctoral Thesis Stockholm, Sweden 2016. URL: https://www.diva-portal.org/smash/get/diva2:1045804/ FULLTEXT01.pdf
Naveed Ur Rehman Malik. Modelling, Analysis, and Control Aspects of a Rotating Power Electronic Brushless Doubly-Fed Induction Generator. Doctoral Thesis in Electrical Machines and Drives. Stockholm, Sweden 2015. URL: https://pdfs.semanticscholar.org/79ee/303c7376f34e7 4357ec593d49c46243204b0.pdf
Galynovskyj A.M. Non-contact asynchronous generator with a modulated frequency converter. Trudy I
Mezhdunarodnoi (III Vserossiiskoi) konferentsii` po Elektromekhanotronike. Sankt-Peterburgskii gosudarstvennyi elektrotekhnicheskii universitet. 1997. Pp. 182-192. (Rus)
Vasyliv K.M. Mathematical model of the dynamic processes of an autonomous electroenergetic system based on a noncontact asynchronized generator with a three-phase three-phase cascade modulated exciter. Tekhnichna Elektrodynamika. 2004. No 5. Pp. 50-55. (Ukr)

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
Copyright (c) 2022 Array