Abstract
A comparative analysis of the electromagnetic vibration disturbing forces occurring in the stator of two- and four-pole powerful turbogenerators operating on nuclear power plants of Ukraine on the basis mathematical model of the electromagnetic field was consider. The spectral analysis of of the electromagnetic vibrational forces was carry out. A spectrum of the electromagnetic vibrational
forces has significant harmonics of frequencies 200, 300, 400 Hz, which are multiples of 100 Hz of the main vibrational force was show. Experimental investigation of the eigenfrequency modes of the end of stator winding was carry out. There is a danger of
response eigenfrequency modes at the specified multiple frequencies. Moreover, due to the design structure of two-pole turbogenerators are more dangerous. References 5, figures 8, tables 2.
References
Abramov A.I., Izvekov V.I., Serihin N.A. Designing of turbogenerators. Moskva: Vysshaia shkola, 1990. 336 p. (Rus)
Vaskovskyi Yu.M., Melnyk A.M. The electromagnetic vibration disturbing forces in turbogenerator with a glance of current asymmetry of stator winding. Tekhnichna Elektrodynamika. 2017. No 1. Pp. 52-57. (Ukr) DOI: https://doi.org/10.15407/techned2017.01.052
Vaskovskyi Yu.M., Shumilov Yu.A., Shtogrin A.V. Analysis of vibration-exciting axial forces in a powerful turbogenerator stator core. Electrical engineering & Electromechanics. 2009. No 2. Pp. 21-26. (Rus)
Milykh V.I., Pototskyi D.V. The numerical-field analysis of power and energy processes in the turbo-generator at load unbalance. Tekhnichna Elektrodynamika. 2017. No 4. Pp. 29-35. (Rus) DOI: https://doi.org/10.15407/techned2017.04.029
URL: http://atominfo.bg/wp-content/uploads/2012/01/GigaTop.pdf (Accessed 11.06.2018).

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
Copyright (c) 2022 Tekhnichna Elektrodynamika