Abstract

Many of possible modes of operation of the AC voltage stabilizer with a transformer-and-switches executive structure containing a transforming element (TE) with a sectioned winding (tap chanching transformer) have been analyzed. The possibility and expediency of loading of the operating modes have been substantiated by increasing the design current density in the winding sections to increase the efficiency of using the installed power of the selected transforming element. The dependence of this indicator on the version of control of the stabilized voltage level is determined. A multiphysics modeling of thermal conditions of TE was carried out. Herewith, an increase in the maximum output power of the device is achieved at the level of 12,5-27% without changing the selected core size while ensuring its nominal thermal regime. References 10, tables 3, figures 4.

https://doi.org/10.15407/techned2017.03.035
ARTICLE_5_PDF (Українська)

References

Belopolsckyi I.I., Karetnikova E.I., Pikalova L.G. Calculation of low-power transformers and reactors. – Мoskva: Energiia, 1973. – 400 p. (Rus)

Borisenko A.I., Kostikov О.N., Yakovlev А.I. Cooling of industrial electric machinery. – Moskva: Energoatomizdat, 1983. – 296 p. (Rus)

Lypkivskyi K.O., Mozharovskyi A.G. Simulation of the transformative elements with sectioning of the windings as part of AC voltage source converters // Tekhnichna Elektrodynamika. – 2016. – No 3. – Pp. 39–44. (Ukr)

Lypkivskyi K.O., Mozharovskyi A.G. Implementation features of the transfer function of the transformerand-switches executive structure of the AC voltage regulator-stabilizer // Tekhnichna Elektrodynamika. – 2017. – No 2. – Pp. 35–39. (Ukr) DOI: https://doi.org/10.15407/techned2017.02.035

GOST 27427.1-83 Rolled Electrical Steel. (Rus)

Bimal, K. Bose. Power Electronics – Why the Field is so Exciting // IEEE Power Electronics Society Newsletter Fourth Quarter. – 2007. – Vol. 19. – No 4. – Pp. 11–20. 7. Comsol Multiphysics – http://www.comsol.com .

Willems W., Vandoorn T.L., De Kooning, J. D., Vandevelde L. Development of a smart transformer to control the power exchange of a microgrid // IEEE PES ISGT Europe 2013. – Pp. 1–5.

Electronic Tap Switching Voltage Regulator. Available at: http://www.ustpower.com/comparing-automaticvoltage-regulation-technologies/avr-guide-electronic-tap-switching-voltage-regulator/ (accessed 15.03.2017).

Engineering articles. Tap chanching transformers. Available at: http://top10electrical.blogspot.com/ (accessed

03.2017).

Creative Commons License

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.

Copyright (c) 2022 Array

Abstract views: 79 | PDF Downloads: 5

Downloads