Abstract

The conditions necessary to provide the robust stability and robust control of synchronous machine’s excitation control with magnitude-phase automatic voltage regulator are determined. References 4, figures 1.

ARTICLE_13_PDF

References

Butkevych O.F. Problem-oriented monitoring of Ukrainian IPS operation conditions. // Tekhnichna Elektrodynamika. − 2007. − No 5. − Pp. 39-52. (Ukr.)

Kundur P. Power System Stability and Control. − New York: McGraw-Hill, 1994. − 1176 p.

Skogestad S., Postlethwaite I. Multivariable Feedback Control Analysis and Design. − Chichester: John Wiley&Sons, 2001. − 572 p.

Yurganov A.A., Kozhevnikov V.A. Excitation Control of Synchronous Generators. − St.-Petersburg: Nauka, 1996. − 138 p.

(Rus)